Din 5480 Calculator -
Applies deviations from embedded database.
: [ d_b = d \cdot \cos\alpha ]
: [ e_{\min} = s_{\max} \quad \text{(for fit H/h)} ] For H/h: (e_{\min} = \frac{\pi m}{2} + \text{allowance}) (from tolerance class table) din 5480 calculator
Checks interference conditions.
: [ d_{fe} = d - 2 \cdot m \cdot (h_{fP}^* + \rho_{fP}^ /m) ] where (h_{fP}^ = 0.45 + c^ ), (c^ = 0.25), (\rho_{fP}^* = 0.2) (fillet radius coefficient). Applies deviations from embedded database
: (d_{ref}=30) mm, (z=20), α=30°, fit H/h, grade 6 Expected: m=1.5, (d_{ae}=33.3) mm, (d_{fe}=26.25) mm, tooth thickness nominal 2.356 mm, allowance 0 to -0.032 mm. (c^ = 0.25)